top of page

Z200 PV Analyzer – features

  • Measure position of a single ground fault in a PV string (Riso < 3 MΩ)
  • Measure position of a single disconnect in PV strings (Rs > 10 kΩ)
  • PV string impedance curves (health and degradation check)
  • PV string series resistance Rs
  • PV string string open circuit voltage Voc
  • PV string string short circuit current Isc
  • PV system isolation resistance Riso
  • PV module voltage
  • PV module bypass diode check (open or short circuit)
  • PV module shunting resistance Rsh (module/cell degradation)
  • Integrated timer for periodic faults
  • Tone generator and tone tracer pickup
  • Build in report generator (PDF, CSV, JSON)
  • Operated over WiFi using either smartphone, tablet, PC or MAC

Packaging list

  • Z200 PV Analyzer
  • Dolphin clamp XDK-1033 red, 1000V – CAT III – 32A
  • Dolphin clamp XDK-1033 black, 1000V – CAT III – 32A
  • Test probe red BT400, 1000V 1A – CATIV
  • Test probe black BT400, 1000V 1A – CATIV
  • Test lead XDLS-418 150cm G/G, m/alligator clamp 1000V CATII 32A
  • PV-test lead, AMLS4/150 red, MC4 connector /Ø4mm banana connector
  • PV-test lead, AMLS4/150 black, MC4 connector /Ø4mm banana connector
  • Test lead, 2,5mm² 1,5m XMS-419, red Sili. 1000V 32A – CATIV
  • Test lead, 2,5mm² 1,5m XMS-419, black Sili. 1000V 32A – CATIV
  • Grounded power cord, Max 2.5A/250V, CEE 7/7, IEC C5
  • Tone Pickup
  • RRC2054 smart battery pack
  • RRC AC adapter
  • SMBUS Mini Battery charger
  • Directives and standards

  • EN 61010-1:2010
  • EN 61010-031:2002
  • EN 61326-1:2013
  • EN 61326-2-2:2013
  • 2006/95/EC, Low Voltage Directive (LVD)
  • 2004/108/EC, Electromagnetic Compatibility (EMC)
  • 2011/65/EU, Hazardous Substances (RoHS)
  • 2006/66/EC, Batteries and Accumulators (Battery)

Solar Photovoltaic field testing and fault finding Tool KIT

﷼4,800.000Price
  • 4 - 6 Weeks from Date of Confirmed Order

  • 4 - 6 Weeks from Date of Confirmed Order

bottom of page